All | OperationalTemplate [rootArchetypeId=openEHR-EHR-CLUSTER.device.v1, otherContributors=null, tshis=[ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1], code=at0000, itemType=CLUSTER, level=0, text=ETT, description=An instrument, apparatus, implant, material or similar, used in the provision of healthcare. In this context, a medical device includes a broad range of devices which act through a variety of physical, mechanical, thermal or similar means but specifically excludes devices which act through medicinal means such as pharmacological, metabolic or immunological methods. The scope is inclusive of disposable devices as well as durable or persisting devices that require tracking, maintenance activities or regular calibration, recognising that each type of device has specific data recording requirements., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0001], code=at0001, itemType=ELEMENT, level=1, text=Device name, description=Identification of the medical device, preferably by a common name, a formal fully descriptive name or, if required, by class or category of device., comment=This data element will capture the term, phrase or category used in clinical practice. For example: <brand name><machine> (XYZ Audiometer); <size> <brand name> <intravenous catheter> (14G Jelco IV catheter); or <brand name/type> <implant>. Coding with a terminology is desirable, where possible, although this may be local and depending on local supplies available., uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0003], code=at0003, itemType=ELEMENT, level=1, text=Type, description=The category or kind of device., comment=Not applicable if a category is already recorded in 'Device name'.
Example: if the 'Device' is named as a 'urinary catheter'; the 'Type' may be recorded as 'indwelling' or 'condom'.Coding with a terminology is desirable, where possible. This may include use of GTIN or EAN numbers., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0002], code=at0002, itemType=ELEMENT, level=1, text=Description, description=Narrative description of the medical device., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0], code=at0000, itemType=CLUSTER, level=1, text=Endotracheal tube (ETT), description=Details about a flexible plastic tube that is inserted inside the trachea to secure an airway., comment=Most typically used as part of a breathing system in anaesthesia or mechanical ventilation., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0001], code=at0001, itemType=ELEMENT, level=2, text=Type??? Cuffed?, description=The type of ETT., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0016], code=at0016, itemType=ELEMENT, level=2, text=Insertion site, description=The body site where the ETT enters the body., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0022], code=at0022, itemType=ELEMENT, level=2, text=Connector type, description=The type of connection between the ETT and the breathing system., comment=For example: push fit; Luerlock., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values= Value set: external, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0006], code=at0006, itemType=ELEMENT, level=2, text=Connector size, description=The size of the connection between the ETT and the breathing system., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=- QuantityUnits: mm
- Coded Text
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0023], code=at0023, itemType=ELEMENT, level=2, text=Number of cuffs (/??lumen) Is there ever one cuff with 2 lumen?, description=The number of cuffs manufactured., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_COUNT, bindings=null, values=0..2, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0005], code=at0005, itemType=ELEMENT, level=2, text=Radiopaque, description=Does the ETT contain radiopaque material?, comment=Allows identification of the tube tip position on Xray., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0024], code=at0024, itemType=ELEMENT, level=2, text=Laser resistant, description=Is the ETT manufactured from laser resistant material?, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012], code=at0012, itemType=CLUSTER, level=2, text=Per lumen, description=Details relevant to a single lumen., comment=null, uncommonOntologyItems=null, occurencesFormal=1..2, occurencesText=Mandatory, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012]/items[at0015], code=at0015, itemType=ELEMENT, level=3, text=?Label/Lumen name, description=Unique name to identify the lumen., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values= Value set: external, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012]/items[at0026], code=at0026, itemType=ELEMENT, level=3, text=Cuff position, description=The location of the cuff in situ., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012]/items[at0013], code=at0013, itemType=ELEMENT, level=3, text=Internal diameter, description=The measured internal diameter of the lumen., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=>=0 mm, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012]/items[at0025], code=at0025, itemType=ELEMENT, level=3, text=External diameter, description=The measured external diameter of the lumen., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=>=0 mm, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012]/items[at0004], code=at0004, itemType=ELEMENT, level=3, text=?Manufactured length, description=The measured length of the lumen at manufacture., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=0..50 cm, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012]/items[at0032], code=at0032, itemType=ELEMENT, level=3, text=Reinforced, description=Is the ETT lumen reinforced?, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012]/items[at0009], code=at0009, itemType=ELEMENT, level=3, text=Murphy's eye, description=Presence of an alternate gas passage in case the ETT tip becomes occluded., comment=null, uncommonOntologyItems=null, occurencesFormal=0..2, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012]/items[at0029], code=at0029, itemType=ELEMENT, level=3, text=Cuff capacity, description=*, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=>=0 ml, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.endotracheal_tube.v0]/items[at0012]/items[at0014], code=at0014, itemType=ELEMENT, level=3, text=Cuff type, description=*, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=- High Pressure Low Volume
- Low Pressure High Volume
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0021], code=at0021, itemType=ELEMENT, level=1, text=Unique device identifier (UDI), description=A numeric or alphanumeric string that is associated with this device within a given system., comment=Often fixed to the device as a barcode., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_IDENTIFIER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0004], code=at0004, itemType=ELEMENT, level=1, text=Manufacturer, description=Name of manufacturer., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0005], code=at0005, itemType=ELEMENT, level=1, text=Date of manufacture, description=Date the device was manufactured., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_DATE_TIME, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0020], code=at0020, itemType=ELEMENT, level=1, text=Serial number, description=Number assigned by the manufacturer which can be found on the device, and should be specific to each device., its label, or accompanying packaging., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0022], code=at0022, itemType=ELEMENT, level=1, text=Catalogue number, description=The exact number assigned by the manufacturer, as it appears in the manufacturer's catalogue, device labeling, or accompanying packaging., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0023], code=at0023, itemType=ELEMENT, level=1, text=Model number, description=The exact model number assigned by the manufacturer and found on the device label or accompanying packaging., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0006], code=at0006, itemType=ELEMENT, level=1, text=Batch/Lot number, description=The number assigned by the manufacturer which identifies a group of items manufactured at the same time, usually found on the label or packaging material., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0025], code=at0025, itemType=ELEMENT, level=1, text=Software version, description=Identification of the version of software being used in the medical device., comment=When the medical device is an actual software application, record the version of the software using this data element. When the medical device has multiple software applications embedded within it, record each software component in a separate CLUSTER archetype within the Components SLOT - either as a nested instance of another CLUSTER.device archetype or using a CLUSTER archetype designed specifically for recording software details (but not yet available at time of this archetype development)., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0007], code=at0007, itemType=ELEMENT, level=1, text=Date of expiry, description=Date after which the device/product is no longer fit for use, usually found on the device itself or printed on the accompanying packaging., comment=This date usually applies only to single use or disposable devices., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_DATE_TIME, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0024], code=at0024, itemType=ELEMENT, level=1, text=Other identifier, description=Unspecified identifier, which can be further specified in a template or at run time., comment=Coding of the name of the identifier with a coding system is desirable, if available., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_IDENTIFIER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-CLUSTER.device.v1]/items[at0008], code=at0008, itemType=ELEMENT, level=1, text=Comment, description=Additional narrative about the device not captured in other fields., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null]], templateType=normal] |