| TEMPLATE ID | Acquisition and validation of VF test |
|---|---|
| Concept | Acquisition and validation of VF test |
| Description | Register the acquisition procedure and outcome for the visual field test. |
| Purpose | Register the acquisition procedure and outcome for the visual field test. |
| References | |
| Other Details (Language Independent) |
|
| Language used | en |
| Citeable Identifier | 1013.26.142 |
| Root archetype id | openEHR-EHR-SECTION.clinical_image_acquisition.v0 |
| Clinical image acquisition and validation VF test | Clinical image acquisition and validation VF test: Manages the acquisition and validation of diagnostic tests based on medical imaging. |
| Visual field measurement | Visual field measurement: Results of visual field testing / perimetry. |
| Data | |
| Any event | Any event: Any measurement event. |
| Data | |
| Clinical Description | Clinical Description: A term, commonly coded, expressing an overall interpretation of the visual field test. |
| Test Result | Test Result: Details of the visual field test result for each eye. |
| Eye | Eye: The eye which is being examined.
|
| Glaucoma Hemifield Test (GHT) | Glaucoma Hemifield Test (GHT): A coded intepretation of the Glaucoma Hemifield Test (GHT).
|
| Visual Field Index | Visual Field Index: Visual Field Index result.
|
| Mean deviation | Mean deviation: The average of deviation in vusual field across all test areas. -30..10 dB |
| Mean deviation P | Mean deviation P: The P value of the Mean Deviation result.
|
| Pattern Standard deviation | Pattern Standard deviation: Average of non-uniform visual field loss. 0..25 dB |
| Pattern Standard deviation P | Pattern Standard deviation P: The P value of the Pattern Standard deviation result.
|
| Clinical Interpretation | Clinical Interpretation: The test result expressed as a qualitative term, normally coded. |
| Image | Image: A multimedia representaion of the visual field test. |
| Overall Interpretation | Overall Interpretation: A term, commonly coded, expressing an overall interpretation of the visual field test. |
| Additional Comment | Additional Comment: Any additional narrative comment about the visual field test. |
| State | |
| Confounding Factors | Confounding Factors: Patient circumstances which may affect interpretation of the result. |
| Protocol | |
| Perimetry Method | Perimetry Method: The method used to record the perimetry result.
|
| Acquisition details on visual field test | Acquisition details on visual field test: Defines specific details about perimetry studies. |
| Laterality | Laterality: Eye/s included in the study.
|
| Method | Method: Method chosen to study patient's visual field.
|
| Test Parameters | Test Parameters: Describe the settings parameters chosen for the test. |
| Automated test | Automated test: Automated perimetry or manual test chosen instead. Assumed value: true |
| Test pattern | Test pattern: Test pattern used to distribute visual field measurements during a perimetry study.
|
| Test strategy | Test strategy: Threshold test algorithm chosen to determine patient's sensitivity at each point tested on the visual field.
|
| Screening test mode | Screening test mode: Mode for determining the starting luminance for screening test points.
|
| Device configuration | Device configuration: Configuration of the perimeter during the visual field test. |
| Fixation monitoring strategy | Fixation monitoring strategy: Configuration used to monitor the patient's fixation.
|
| Stimulus | Stimulus: Properties of the light chosen to stimulate patients. |
| Stimulus area | Stimulus area: Area of light stimulus presented to the patient.
|
| Stimulus colour | Stimulus colour: Colour of light stimulus presented to the patient. Value set: ac0001 |
| Background | Background: Properties of the background chosen for the test. |
| Background luminance | Background luminance: Background luminance of the device, in candelas per square meter (cd/m²) or apostilbs (ASB).
|
| Background illumination colour | Background illumination colour: Colour chosen to illuminate the background of the visual field device so as to make the light stimulus contrast optimal. Value set: ac0002 |