TEMPLATE Intraocular pressure study (Intraocular pressure study)

TEMPLATE IDIntraocular pressure study
ConceptIntraocular pressure study
DescriptionTo manage the acquisition procedure and outcome for the intraocular pressure measurement test.
PurposeTo manage the acquisition procedure and outcome for the intraocular pressure measurement test.
References
Authorsname: Aitor Eguzkitza; organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra; email: aitor.eguzkiza@unavarra.es; date: 2016-07-25
Other Details Languagename: Aitor Eguzkitza; organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra; email: aitor.eguzkiza@unavarra.es; date: 2016-07-25
OtherDetails Language Independent{MetaDataSet:Sample Set =Template metadata sample set, Copyright=© openEHR Foundation, Owner=Aitor Eguzkitza, aitor.eguzkiza@unavarra.es, Speciality=Ophthalmology}
Language useden
Citeable Identifier1013.26.141
AllOperationalTemplate [rootArchetypeId=openEHR-EHR-SECTION.intraocular_pressure_study.v0, otherContributors=Jose Andonegui, Complejo hospitalario de Navarra (CHN), jose.andonegui.navarro@cfnavarra.es; Luis Serrano, Universidad Pública de Navarra (UPNA), lserrano@unavarra.es; Jesús D. Trigo, Universidad Pública de Navarra (UPNA), jesusdaniel.trigo@unavarra.es, tshis=[ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0], code=at0000, itemType=SECTION, level=0, text=Intraocular pressure study, description=Defines the process which involves the intraocular pressure acquisition and its study., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=SECTION, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1], code=at0000, itemType=ACTION, level=1, text=Procedure, description=A clinical activity carried out for screening, investigative, diagnostic, curative, therapeutic, evaluative or palliative purposes., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/description[at0001], code=at0001, itemType=UNSUPPORTEDTOPLEVELATTRIBUTE, level=2, text=Description, description=, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=UNSUPPORTEDTOPLEVELATTRIBUTE, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/description[at0001]/items[at0002], code=at0002, itemType=ELEMENT, level=3, text=Procedure name, description=Identification of the procedure by name., comment=Coding of the specific procedure with a terminology is preferred, where possible., uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=Default value: Intraocular pressure measurement, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/description[at0001]/items[at0049], code=at0049, itemType=ELEMENT, level=3, text=Description, description=Narrative description about the procedure, as appropriate for the pathway step., comment=For example: description about the performance and findings from the the procedure, the aborted attempt or the cancellation of the procedure., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=Default value: Carry out the measurement of patient's intraocular pressure., extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/description[at0001]/items[at0065], code=at0065, itemType=ELEMENT, level=3, text=Method, description=Identification of specific method or technique for the procedure., comment=Use this data element to record simple terms or a narrative description. If the requirements for recording the method require more complex modelling then this can be represented by additional archetypes within the 'Procedure detail' SLOT in this archetype. If the method is included in the 'Procedure name' via precoordinated codes, this data element becomes redundant., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/description[at0001]/items[at0058], code=at0058, itemType=ELEMENT, level=3, text=Urgency, description=Urgency of the procedure., comment=Coding with a terminology is preferred, where possible., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/description[at0001]/items[at0066], code=at0066, itemType=ELEMENT, level=3, text=Scheduled date/time, description=The date and/or time on which the procedure is intended to be performed., comment=Only for use in association with the 'Procedure scheduled' pathway step., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_DATE_TIME, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/description[at0001]/items[at0060], code=at0060, itemType=ELEMENT, level=3, text=Final end date/time, description=The date and/or time when the entire procedure, or the last component of a multicomponent procedure, was finished., comment=Only for use in association with the 'Procedure performed' pathway step, and in situations where the procedure is repeated on multiple occasions before being completed or there are multiple components to the whole procedure. This may be the same as the RM time attribute for the 'Procedure completed' pathway step., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_DATE_TIME, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/description[at0001]/items[at0014], code=at0014, itemType=ELEMENT, level=3, text=Reason, description=Reason that the activity or care pathway step for the identified procedure was carried out., comment=For example: the reason for the cancellation or suspension of the procedure., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=
  • DR screening
  • Monitor the progression of chronic glaucoma
  • Routine eye consultation
  • Other reason
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/description[at0001]/items[at0005], code=at0005, itemType=ELEMENT, level=3, text=Comment, description=Additional narrative about the activity or care pathway step not captured in other fields., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/protocol[at0053], code=at0053, itemType=UNSUPPORTEDTOPLEVELATTRIBUTE, level=2, text=Protocol, description=, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=UNSUPPORTEDTOPLEVELATTRIBUTE, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/protocol[at0053]/items[at0054], code=at0054, itemType=ELEMENT, level=3, text=Requestor order identifier, description=The local ID assigned to the order by the healthcare provider or organisation requesting the service., comment=This is equivalent to Placer Order Number in HL7 v2 specifications., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=
  •  Text
  •  Identifier
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-ACTION.procedure.v1]/protocol[at0053]/items[at0056], code=at0056, itemType=ELEMENT, level=3, text=Receiver order identifier, description=The ID assigned to the order by the healthcare provider or organisation receiving the request for service. This is also referred to as Filler Order Identifier., comment=This is equivalent to Filler Order Number in HL7 v2 specifications., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=
  •  Text
  •  Identifier
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0], code=at0000, itemType=OBSERVATION, level=1, text=Intraocular pressure, description=The local measurement of intraocular pressure, most commonly using a tonometry device., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=OBSERVATION, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001], code=at0001, itemType=UNSUPPORTEDTOPLEVELATTRIBUTE, level=2, text=Data, description=, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=UNSUPPORTEDTOPLEVELATTRIBUTE, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001]/events[at0002], code=at0002, itemType=EVENT, level=3, text=Any event, description=Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=EVENT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001]/events[at0002]/data[at0003], code=at0003, itemType=UNSUPPORTEDTOPLEVELATTRIBUTE, level=4, text=Data, description=, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=UNSUPPORTEDTOPLEVELATTRIBUTE, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001]/events[at0002]/data[at0003]/items[at0057], code=at0057, itemType=ELEMENT, level=5, text=Eye examined, description=Identification of the eye under examination., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Left 
  • Right 
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001]/events[at0002]/data[at0003]/items[at0042], code=at0042, itemType=ELEMENT, level=5, text=Pressure, description=Measured intraocular pressure., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=0..90 mm[Hg], extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001]/events[at0002]/data[at0003]/items[at0065], code=at0065, itemType=ELEMENT, level=5, text=Applanation time, description=The time taken for a non-contact tonometer to flatten the cornea, used to calculate intraocular pressure., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=>=0 millisec, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001]/events[at0002]/data[at0003]/items[at0061], code=at0061, itemType=ELEMENT, level=5, text=Clinical interpretation, description=Single word, phrase or brief description that represents the clinical meaning and significance of the physical examination findings., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001]/events[at0002]/data[at0003]/items[at0063], code=at0063, itemType=ELEMENT, level=5, text=Comment, description=Additional narrative about the measurement, not captured in other fields., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001]/events[at0002]/state[at0007], code=at0007, itemType=UNSUPPORTEDTOPLEVELATTRIBUTE, level=4, text=State, description=, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=UNSUPPORTEDTOPLEVELATTRIBUTE, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/data[at0001]/events[at0002]/state[at0007]/items[at0074], code=at0074, itemType=ELEMENT, level=5, text=Confounding factors, description=Description of any incidental factors related to the state of the subject which may affect clinical interpretation of the measurement., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068], code=at0068, itemType=UNSUPPORTEDTOPLEVELATTRIBUTE, level=2, text=Protocol, description=, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=UNSUPPORTEDTOPLEVELATTRIBUTE, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[at0046], code=at0046, itemType=ELEMENT, level=3, text=Tonometry Method, description=Type of tonometery used to measure intracoular pressure., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=
  •  Coded Text
    • Goldmann 
    • Perkins 
    • Tono-Pen 
    • Icare (Rebound) 
    • Dynamic Contour 
    • Ocular Response Analyzer 
    • TGDc-01 
    • Non-contact tonometry 
  •  Text
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1], code=at0000, itemType=CLUSTER, level=3, text=Medical Device, description=An instrument, apparatus, implant, material or similar, used in the provision of healthcare. In this context, a medical device includes a broad range of devices which act through a variety of physical, mechanical, thermal or similar means but specifically excludes devices which act through medicinal means such as pharmacological, metabolic or immunological methods. The scope is inclusive of disposable devices as well as durable or persisting devices that require tracking, maintenance activities or regular calibration, recognising that each type of device has specific data recording requirements., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[at0001], code=at0001, itemType=ELEMENT, level=4, text=Device name, description=Identification of the medical device, preferably by a common name, a formal fully descriptive name or, if required, by class or category of device., comment=This data element will capture the term, phrase or category used in clinical practice. For example: <brand name><machine> (XYZ Audiometer); <size> <brand name> <intravenous catheter> (14G Jelco IV catheter); or <brand name/type> <implant>. Coding with a terminology is desirable, where possible, although this may be local and depending on local supplies available., uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[at0003], code=at0003, itemType=ELEMENT, level=4, text=Type, description=The category or kind of device., comment=Not applicable if a category is already recorded in 'Device name'. Example: if the 'Device' is named as a 'urinary catheter'; the 'Type' may be recorded as 'indwelling' or 'condom'.Coding with a terminology is desirable, where possible. This may include use of GTIN or EAN numbers., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[at0002], code=at0002, itemType=ELEMENT, level=4, text=Description, description=Narrative description of the medical device., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[at0021], code=at0021, itemType=ELEMENT, level=4, text=Unique device identifier (UDI), description=A numeric or alphanumeric string that is associated with this device within a given system., comment=Often fixed to the device as a barcode., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_IDENTIFIER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[at0004], code=at0004, itemType=ELEMENT, level=4, text=Manufacturer, description=Name of manufacturer., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[at0005], code=at0005, itemType=ELEMENT, level=4, text=Date of manufacture, description=Date the device was manufactured., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_DATE_TIME, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1], code=at0000, itemType=CLUSTER, level=4, text=Medical device details, description=Specific details that relate to asset management for any medical device that is designed for more than a single use., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0001], code=at0001, itemType=ELEMENT, level=5, text=Organisation identifier, description=Organisation identifier for device., comment=May be a text string or an IEEE EUI-64 identifier., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=
  •  Text
  •  Identifier
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0023], code=at0023, itemType=ELEMENT, level=5, text=Owner, description=Organisation responsible for the medical device., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0024], code=at0024, itemType=ELEMENT, level=5, text=Location, description=Physical location where device is kept., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0025], code=at0025, itemType=ELEMENT, level=5, text=Network address, description=Network address to contact the device., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_URI, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0007], code=at0007, itemType=ELEMENT, level=5, text=Part number, description=The part number of the device., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0002], code=at0002, itemType=ELEMENT, level=5, text=Manufacturer model name, description=HL7 CDA compatible representation of device manufacture details., comment=May be a simple string or contain simple markup e.g. for Continua PHMR reports: "Pulse Master 2000||584216|69854|2.1|1.1|1.0|" repesenting Model, Unspecified, SerialNumber, PartNumber, HardwareRevision, SoftwareRevision, ProtocolRevision, and ProdSpecGMDN., uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0008], code=at0008, itemType=ELEMENT, level=5, text=Hardware revision, description=The hardware revision number., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0010], code=at0010, itemType=ELEMENT, level=5, text=Protocol revision, description=The protocol revision number., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0011], code=at0011, itemType=ELEMENT, level=5, text=Sampling frequency, description=The sampling frequency limits of the device., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=
  •  Text
  •  Quantity
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0012], code=at0012, itemType=ELEMENT, level=5, text=Range, description=The range limits of the device., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=
  •  Text
  •  Interval of Quantity
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0013], code=at0013, itemType=ELEMENT, level=5, text=Accuracy, description=The accuracy limits of the device., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=
  •  Text
  •  Quantity
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0014], code=at0014, itemType=ELEMENT, level=5, text=Resolution, description=The resolution limits of the device., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=
  •  Text
  •  Quantity
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0022], code=at0022, itemType=ELEMENT, level=5, text=Date last cleaned/sterilized, description=Date the device was last cleaned or sterilized., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_DATE_TIME, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0017], code=at0017, itemType=ELEMENT, level=5, text=Date last calibrated, description=Date the device was last calibrated., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_DATE_TIME, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[openEHR-EHR-CLUSTER.device_details.v1]/items[at0016], code=at0016, itemType=ELEMENT, level=5, text=Date last serviced, description=The date the device was last serviced., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_DATE_TIME, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.device.v1]/items[at0008], code=at0008, itemType=ELEMENT, level=4, text=Comment, description=Additional narrative about the device not captured in other fields., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.corneal_thickness_details.v0], code=at0000, itemType=CLUSTER, level=3, text=Central corneal thickness details, description=Measurement details about of the central corneal thickness., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.corneal_thickness_details.v0]/items[at0001], code=at0001, itemType=ELEMENT, level=4, text=Central Corneal Thickness (CCT), description=Value measured of the central corneal thickness., comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=400..700 um, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.corneal_thickness_details.v0]/items[at0002], code=at0002, itemType=ELEMENT, level=4, text=Measurement Method, description=Method used to measure the corneal thickness parameter., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=Value set: ac0001, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-SECTION.intraocular_pressure_study.v0]/items[openEHR-EHR-OBSERVATION.intraocular_pressure.v0]/protocol[at0068]/items[openEHR-EHR-CLUSTER.corneal_thickness_details.v0]/items[at0003], code=at0003, itemType=ELEMENT, level=4, text=Correction parameter, description=Parameter obtained from tables provided by manufacturers, to correct the intraocular pressure value according to the central corneal thickness obtained., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=-7..7 mm[Hg]
Assumed value: 0 mm[Hg], extendedValues=null]], templateType=normal]