archetype (adl_version=1.4; uid=3e7380a1-9378-49f3-a2fa-24a40ffcb287) openEHR-EHR-OBSERVATION.categorical_loudness_scaling.v1 concept [at0000] -- Categorical loudness scaling language original_language = <[ISO_639-1::en]> description original_author = < ["name"] = <"Lena Schell-Majoor"> ["organisation"] = <"University of Oldenburg, Cluster of Excellence Hearing4all"> ["email"] = <"lena.schell-majoor@uni-oldenburg.de"> ["date"] = <"2023-03-23"> > details = < ["en"] = < language = <[ISO_639-1::en]> purpose = <"To record the responses from a categorical loudness scaling assessment and the derived loudness perception curve."> use = <"Use to record an individual's responses to a loudness scaling assessment and the corresponding loudness perception curve. Responses may be aided or unaided."> keywords = <"hearing, audiology, categorial", ...> misuse = <"Not to be used to record any other auditory assessment than categorical loudness scaling. Use the specific archetypes for these purposes."> copyright = <"© openEHR Foundation, HiGHmed, Hearing4all"> > > lifecycle_state = <"published"> other_contributors = <"Mareike Buhl, Eugen Kludt, Birger Kollmeier, Antje Wulff", ...> other_details = < ["licence"] = <"This work is licensed under the Creative Commons Attribution-ShareAlike 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/4.0/."> ["custodian_organisation"] = <"HiGHmed"> ["references"] = <"ISO (2006). 16832:2006, Acoustics - loudness scaling by means of categories. International Organization for Standardization, Geneva, Switzerland. Brand, T., & Hohmann, V. (2002). An adaptive procedure for categorical loudness scaling. The Journal of the Acoustical Society of America, 112(4), 1597-1604. Hellbrück, J., & Moser, L. M. (1986). Psychophysical measurements of inner ear processes with category scaling of loudness. ORL, 48(2), 135-136."> ["original_namespace"] = <"org.highmed"> ["original_publisher"] = <"HiGHmed"> ["custodian_namespace"] = <"org.highmed"> ["MD5-CAM-1.0.1"] = <"E5AAB3A9896DE9CF2B27A23B28206DA0"> ["build_uid"] = <"09e04bd3-2113-4d62-9107-23827814cf6f"> ["revision"] = <"1.0.0"> > definition OBSERVATION[at0000] matches { -- Categorical loudness scaling data matches { HISTORY[at0001] matches { -- History events cardinality matches {1..*; unordered} matches { EVENT[at0002] occurrences matches {0..*} matches { -- Any event data matches { ITEM_TREE[at0003] matches { -- Tree items cardinality matches {0..*; unordered} matches { ELEMENT[at0036] occurrences matches {0..1} matches { -- Frequency of test stimulus value matches { C_DV_QUANTITY < property = <[openehr::382]> list = < ["1"] = < units = <"Hz"> magnitude = <|20.0..20000.0|> precision = <|0|> > ["2"] = < units = <"kHz"> magnitude = <|0.125..16.0|> precision = <|3|> > > > } } ELEMENT[at0027] matches { -- Tested side value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0028, -- Right ear at0029, -- Left ear at0030] -- Binaural } } } } CLUSTER[at0035] occurrences matches {0..*} matches { -- Measurement items cardinality matches {1..*; unordered} matches { ELEMENT[at0110] matches { -- Stimulus level value matches { C_DV_QUANTITY < property = <[openehr::123]> list = < ["1"] = < units = <"dB[SPL]{HL}"> magnitude = <|-50.0..200.0|> precision = <|2|> > > > } } ELEMENT[at0111] matches { -- Response category value matches { C_DV_QUANTITY < property = <[openehr::755]> list = < ["1"] = < units = <"[arb'U]{CU}"> magnitude = <|0.0..1000.0|> precision = <|1|> > > > } } } } CLUSTER[at0101] occurrences matches {0..*} matches { -- Loudness perception curve items cardinality matches {1..*; unordered} matches { ELEMENT[at0139] occurrences matches {0..1} matches { -- Fit procedure name value matches { DV_TEXT matches {*} } } CLUSTER[at0136] occurrences matches {0..*} matches { -- Curve sample items cardinality matches {1..*; unordered} matches { ELEMENT[at0138] matches { -- Response category value matches { C_DV_QUANTITY < property = <[openehr::755]> list = < ["1"] = < units = <"[arb'U]{CU}"> magnitude = <|0.0..1000.0|> precision = <|2|> > > > } } ELEMENT[at0137] matches { -- Stimulus level value matches { C_DV_QUANTITY < property = <[openehr::123]> list = < ["1"] = < units = <"dB[SPL]{HL}"> magnitude = <|-50.0..200.0|> precision = <|0|> > > > } } } } ELEMENT[at0140] occurrences matches {0..1} matches { -- Curve equation value matches { DV_TEXT matches {*} } } ELEMENT[at0103] occurrences matches {0..1} matches { -- Lower slope value value matches { C_DV_QUANTITY < property = <[openehr::755]> list = < ["1"] = < units = <"[arb'U]{CU}/dB[SPL]{HL}"> magnitude = <|0.0..100.0|> precision = <|0|> > > > } } ELEMENT[at0149] occurrences matches {0..1} matches { -- Upper slope value value matches { C_DV_QUANTITY < property = <[openehr::755]> list = < ["1"] = < units = <"[arb'U]{CU}/dB[SPL]{HL}"> magnitude = <|0.0..100.0|> precision = <|0|> > > > } } ELEMENT[at0150] occurrences matches {0..1} matches { -- Curve comment value matches { DV_TEXT matches {*} } } } } ELEMENT[at0133] occurrences matches {0..1} matches { -- Overall comment value matches { DV_TEXT matches {*} } } allow_archetype CLUSTER[at0157] occurrences matches {0..*} matches { -- No test result include archetype_id/value matches {/openEHR-EHR-CLUSTER\.exclusion_exam\.v1/} } } } } state matches { ITEM_TREE[at0119] matches { -- Item tree items cardinality matches {0..*; unordered} matches { CLUSTER[at0142] occurrences matches {0..*} matches { -- Hearing device during test items cardinality matches {1..*; unordered} matches { allow_archetype CLUSTER[at0083] matches { -- Hearing device include archetype_id/value matches {/openEHR-EHR-CLUSTER\.device\.v1/} } ELEMENT[at0143] matches { -- Side of hearing device value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0145, -- Left at0146] -- Right } } } } ELEMENT[at0144] occurrences matches {0..1} matches { -- Comment value matches { DV_TEXT matches {*} } } } } ELEMENT[at0151] occurrences matches {0..1} matches { -- Confounding factors value matches { DV_TEXT matches {*} } } } } } } } } } protocol matches { ITEM_TREE[at0060] matches { -- Item tree items cardinality matches {0..*; unordered} matches { ELEMENT[at0095] occurrences matches {0..1} matches { -- Scaling method value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0096, -- Adaptive Categorical Loudness Scaling (ACALOS) at0097, -- Würzburger Hörfeldskalierung at0152] -- Loudness growth in 1/2 octave bands (LGOB) } } DV_TEXT matches {*} } } ELEMENT[at0128] occurrences matches {0..1} matches { -- Presentation method value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0129, -- Loudspeaker at0130, -- Insert earphone at0131, -- Headphone at0153] -- Direct streaming to sound processor } } DV_TEXT matches {*} } } allow_archetype CLUSTER[at0082] occurrences matches {0..1} matches { -- Presentation method details include archetype_id/value matches {/openEHR-EHR-CLUSTER\.device\.v1/} } ELEMENT[at0075] occurrences matches {0..1} matches { -- Type of test stimulus value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0076, -- Tone burst at0077, -- Click at0078, -- Warble tone at0079, -- Pure tone at0080, -- Narrowband noise at0081, -- Pulsed pure tone at0127, -- Broadband noise at0135, -- Natural sound at0156] -- Low-noise narrowband noise } } DV_TEXT matches {*} } } ELEMENT[at0134] occurrences matches {0..1} matches { -- Name of test stimulus value matches { DV_TEXT matches {*} } } ELEMENT[at0069] occurrences matches {0..1} matches { -- Test environment value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0070, -- Sound treated room at0071, -- Non-sound treated room at0126] -- Free-field } } DV_TEXT matches {*} } } allow_archetype CLUSTER[at0147] occurrences matches {0..*} matches { -- Test environment details include archetype_id/value matches {/openEHR-EHR-CLUSTER\.device\.v1/} } } } } } ontology term_definitions = < ["en"] = < items = < ["at0000"] = < text = <"Categorical loudness scaling"> description = <"A psychophysical method used to assess an individual's perception of loudness to acoustic stimuli of varying levels."> > ["at0001"] = < text = <"History"> description = <"@ internal @"> > ["at0002"] = < text = <"Any event"> description = <"Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time."> > ["at0003"] = < text = <"Tree"> description = <"@ internal @"> > ["at0027"] = < text = <"Tested side"> description = <"Identification of the tested ear(s)."> > ["at0028"] = < text = <"Right ear"> description = <"The test stimuli were presented to the right ear."> > ["at0029"] = < text = <"Left ear"> description = <"The test stimuli were presented to the left ear."> > ["at0030"] = < text = <"Binaural"> description = <"The test stimuli were presented to both ears simultaneously."> > ["at0035"] = < text = <"Measurement"> description = <"The reported loudness category for a given stimulus level."> > ["at0036"] = < text = <"Frequency of test stimulus"> description = <"Frequency of stimulus tested if applicable."> comment = <"Provide further specification of 'Type of test stimulus', if a frequency is required. For example: frequency of pure tone or center frequency of narrowband noise. "> > ["at0060"] = < text = <"Item tree"> description = <"@ internal @"> > ["at0069"] = < text = <"Test environment"> description = <"The environment in which the audiometric test is administered."> comment = <"This data element is commonly used in industry hearing programs."> > ["at0070"] = < text = <"Sound treated room"> description = <"Test environment that has been treated acoustically."> > ["at0071"] = < text = <"Non-sound treated room"> description = <"Test environment that has not been treated acoustically."> > ["at0075"] = < text = <"Type of test stimulus"> description = <"Identification of the stimulus used in the categorical loudness scaling procedure."> comment = <"If the type of stimulus is broadband, use 'Name of test stimulus' for further specification. If the type of noise is a tone or a narrowband noise, use 'Frequency of test stimulus' for further specification."> > ["at0076"] = < text = <"Tone burst"> description = <"The test stimulus is a tone burst."> > ["at0077"] = < text = <"Click"> description = <"The test stimulus is a click."> > ["at0078"] = < text = <"Warble tone"> description = <"The test stimulus is a frequency modulated tone."> > ["at0079"] = < text = <"Pure tone"> description = <"The test stimulus is a pure tone."> > ["at0080"] = < text = <"Narrowband noise"> description = <"The test stimulus is a narrow band noise centred on the specified frequency."> > ["at0081"] = < text = <"Pulsed pure tone"> description = <"The test stimulus is a pulsed pure tone."> > ["at0082"] = < text = <"Presentation method details"> description = <"Details of device used to present test stimulus as specified in 'Presentation method'."> comment = <"For example: type of headphone or speaker."> > ["at0083"] = < text = <"Hearing device"> description = <"Details of the hearing device used."> comment = <"For example: hearing aid or cochlear implant as type of device."> > ["at0095"] = < text = <"Scaling method"> description = <"Choice of scaling method."> comment = <"The scaling method includes details on the experimental procedure. For example: verbal descriptions of response categories."> > ["at0096"] = < text = <"Adaptive Categorical Loudness Scaling (ACALOS)"> description = <"Method by Brand & Hohmann 2002."> > ["at0097"] = < text = <"Würzburger Hörfeldskalierung"> description = <"Method by Hellbrück & Moser 1985."> > ["at0101"] = < text = <"Loudness perception curve"> description = <"Loudness perception curve fitted to measured data."> comment = <"It can either be described through sampled data points from the curve (pairs of response category and stimulus level), or the curve equation and corresponding fit parameters (slope values and specific curve samples)."> > ["at0103"] = < text = <"Lower slope value"> description = <"Slope value for lower section of fitted loudness perception curve corresponding to 'Curve equation'."> comment = <"Use this parameter, if only one slope value is required. For example: in case of a linear curve."> > ["at0110"] = < text = <"Stimulus level"> description = <"The level of the stimulus."> > ["at0111"] = < text = <"Response category"> description = <"The reported loudness category for a given stimulus level."> > ["at0119"] = < text = <"Item tree"> description = <"@ internal @"> > ["at0126"] = < text = <"Free-field"> description = <"Room with free-field characteristics, also called 'anechoic room'."> > ["at0127"] = < text = <"Broadband noise"> description = <"The test stimulus is a broad band noise."> > ["at0128"] = < text = <"Presentation method"> description = <"The method used to present the test stimulus."> > ["at0129"] = < text = <"Loudspeaker"> description = <"The stimulus is presented via a loudspeaker."> > ["at0130"] = < text = <"Insert earphone"> description = <"The stimulus is presented via insert earphones."> > ["at0131"] = < text = <"Headphone"> description = <"The stimulus is presented via external headphones - either circumaural or supraaural."> > ["at0133"] = < text = <"Overall comment"> description = <"Additional narrative about the measurement of categorical loudness scaling not captured in other fields."> comment = <"For example: if measurement was not completed or maximum level was reached."> > ["at0134"] = < text = <"Name of test stimulus"> description = <"Further specification of test stimulus if applicable."> comment = <"Provides name of test stimulus, if it has an established name or description of natural sound. For example: IFNoise, Icra1 or, for natural sounds, birds."> > ["at0135"] = < text = <"Natural sound"> description = <"The test stimulus is a natural/recorded sound."> > ["at0136"] = < text = <"Curve sample"> description = <"Data point of fitted loudness perception curve represented by a combination of a given response category and corresponding stimulus level."> comment = <"These data points can be used to describe the curve through sampled data points or as fit parameters included in the curve equation. For example: response category of 2.5 CU, 25 CU and 50 CU. "> > ["at0137"] = < text = <"Stimulus level"> description = <"The stimulus level for the chosen CU value of fitted loudness perception curve."> > ["at0138"] = < text = <"Response category"> description = <"The chosen loudness category of the curve sample."> comment = <"For example: 2.5 CU, 25 CU, 50 CU."> > ["at0139"] = < text = <"Fit procedure name"> description = <"Name of the procedure applied to fit the loudness function to the data."> comment = <"A literature reference could be included if applicable. For example: \"BX\" from Oetting et al. 2014 or exponential fit."> > ["at0140"] = < text = <"Curve equation"> description = <"Equation for loudness perception curve with explanation of included variables."> comment = <"Include reference in 'Type of fit' if applicable."> > ["at0142"] = < text = <"Hearing device during test"> description = <"Information about hearing device use during loudness scaling test."> > ["at0143"] = < text = <"Side of hearing device"> description = <"Identification of the side where the hearing device is worn during the test."> > ["at0144"] = < text = <"Comment"> description = <"Additional information about the hearing device that is not captured in \"Hearing device\" or \"Side of hearing device\"."> comment = <"For example: information about hearing device settings."> > ["at0145"] = < text = <"Left"> description = <"The hearing device is worn at the left side."> > ["at0146"] = < text = <"Right"> description = <"The hearing device is worn at the right side."> > ["at0147"] = < text = <"Test environment details"> description = <"Additional details of 'Test environment'."> comment = <"For example: specific audiometric booth or a free text description of the room's sound treatment."> > ["at0149"] = < text = <"Upper slope value"> description = <"Slope value for upper section of fitted loudness perception curve corresponding to 'Curve equation'."> > ["at0150"] = < text = <"Curve comment"> description = <"Additional narrative about the loudness perception curve not captured in other fields."> comment = <"For example: other parameters used to describe the loudness curve."> > ["at0151"] = < text = <"Confounding factors"> description = <"Additional issues or factors that may impact loudness scaling tests, not captured in other fields."> comment = <"For example: medication or noise exposure prior to test."> > ["at0152"] = < text = <"Loudness growth in 1/2 octave bands (LGOB)"> description = <"Method by Allen et al. 1990."> > ["at0153"] = < text = <"Direct streaming to sound processor"> description = <"The stimulus is directly streamed to the sound processor of a hearing device."> > ["at0156"] = < text = <"Low-noise narrowband noise"> description = <"The test stimulus is a low-noise narrowband noise centred on the specified frequency."> > ["at0157"] = < text = <"No test result"> description = <""> > > > >