ARCHETYPE Catheter lumen (openEHR-EHR-CLUSTER.catheter_lumen.v0)

ARCHETYPE IDopenEHR-EHR-CLUSTER.catheter_lumen.v0
ConceptCatheter lumen
DescriptionDetails about a lumen of a catheter or tubular medical device.
UseUse to record details about a lumen within a catheter or tube, whether single-lumen or multi-lumen. For single-lumen devices, use this archetype once to capture the lumen properties. For multi-lumen devices, use this archetype multiple times, once for each lumen. This archetype is designed to be nested within the CLUSTER.device_catheter archetype or similar device property archetypes.
MisuseNot to be used to document insertion techniques or procedural steps; use ACTION.procedure instead.
PurposeTo record the physical and functional properties of a lumen within a catheter or tubular medical device.
References
Copyright© openEHR Foundation
AuthorsAuthor name: Heather Leslie
Organisation: Atomica Informatics
Email: heather.leslie@atomicainformatics.com
Date originally authored: 2021-05-04
Other Details LanguageAuthor name: Heather Leslie
Organisation: Atomica Informatics
Email: heather.leslie@atomicainformatics.com
Date originally authored: 2021-05-04
Other Details (Language Independent)
  • Licence: This work is licensed under the Creative Commons Attribution-ShareAlike 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/4.0/.
  • Custodian Organisation: openEHR Foundation
  • Original Namespace: org.openehr
  • Original Publisher: openEHR Foundation
  • Custodian Namespace: org.openehr
  • MD5-CAM-1.0.1: 624491A86B8058E11B74B058CE22A80B
  • Build Uid: 682402c6-fcb6-41d9-bcc0-ccdf5404bb19
  • Revision: 0.0.1-alpha
Keywords
Lifecyclein_development
UID3452a121-3b59-4f4d-ad6d-581f1a607ecd
Language useden
Citeable Identifier1013.1.8223
Revision Number0.0.1-alpha
items
LabelLabel: A label or identifier for this lumen.
For example: 'main', 'distal', 'proximal', 'vent', or 'suction'.
Internal diameterInternal diameter: The internal diameter of this lumen.
Property: Length
Units: >=0.0 mm
LengthLength: The length or depth of this lumen.
Property: Length
Units: >=0.0 cm
PurposePurpose: The primary function or purpose of this lumen.
  • Airway [The lumen is used for airway management.]
  • Medication delivery [The lumen is used for delivery of medications.]
  • Fluid administration [The lumen is used for administration of fluids.]
  • Monitoring/pressure [The lumen is used for monitoring or pressure measurement.]
  • Drainage [The lumen is used for drainage of fluids.]
ConnectorConnector: Details about the connector for this lumen.
More than one connector may be relevant when a single lumen has both a primary hub and one or more additional access points, such as an extension connector, sampling port, or needleless access connector.
TypeType: The type of connector used for this lumen.
  • Push-fit [A push-fit connector.]
  • Luer-lock [A Luer-lock connector.]
  • Slip-fit [A slip-fit connector.]
SizeSize: The size of the connector for this lumen.
Choice of:
  •  Quantity
    Property: Length
    Units: >=0.0 mm
  •  Coded Text
Other contributors
Translators
  • Norwegian Bokmål: