| ARCHETYPE ID | openEHR-EHR-CLUSTER.intraocular_pressure_test_reliability_indicator.v0 |
|---|---|
| Concept | Intraocular pressure test reliability indicator |
| Description | intraocular pressure test reliability indicator |
| Purpose | To record outputs indicating the reliability of an intraocular pressure test. |
| References | Vantomme M, Pourjavan S, Detry-Morel M. The range of the waveform score of the ocular response analyzer (ora) in healthy subjects. Bull Soc Belge Ophtalmol. 2013;(322):91–7. |
| Copyright | © openEHR Foundation |
| Authors | Author name: Lars Fuhrmann Organisation: Deutsche Ophthalmologische Gesellschaft Email: lars.fuhrmann@dog.org Date originally authored: 2026-02-07 |
| Other Details Language | Author name: Lars Fuhrmann Organisation: Deutsche Ophthalmologische Gesellschaft Email: lars.fuhrmann@dog.org Date originally authored: 2026-02-07 |
| Other Details (Language Independent) |
|
| Keywords | IOP, Intraocular Pressure, Reliability |
| Lifecycle | in_development |
| UID | 578f81c1-0b12-4e35-9890-af38b4dfdfa3 |
| Language used | en |
| Citeable Identifier | 1013.1.8183 |
| Revision Number | 0.0.1-alpha |
| items | |
| Ocular Reponse Analyzer Waveform Score | Ocular Reponse Analyzer Waveform Score: Waveform score produced by the Ocular Response Analyzer device.
Higher values indicate higher reliability. Property: null Units: 0.0..10.0 arb. unit Limit decimal places: 2 |
| 7CR Reliability Score | 7CR Reliability Score: Reliability score produced by the Reichert® 7CR device.
Higher values indicate higher reliability. Property: null Units: 0.0..10.0 arb. unit Limit decimal places: 2 |
| Tonopen AVIA Statistical Confidence Indicator | |
| iCare measurement quality color indicator | iCare measurement quality color indicator: 1: Green [Good measurement quality] 2: Yellow [Acceptable measurement Quality] |