ARCHETYPE Electrophysiology (openEHR-EHR-CLUSTER.electrophysiology_experiment.v0)

ARCHETYPE IDopenEHR-EHR-CLUSTER.electrophysiology_experiment.v0
ConceptElectrophysiology
DescriptionProperties for describing an electrophysiological experiment.
PurposeDescribes basic atributtes of electrophysilogy experiments according to odML terminology.
ReferencesBased on odML terminology http://portal.g-node.org/odml/terminologies/v1.0/experiment/electrophysiology.xml, v.1.0, d. 2012-01-02
Copyright© openEHR Foundation
AuthorsAuthor name: Václav Papež
Organisation: University of West Bohemia
Email: vpapez@kiv.zcu.cz
Date originally authored: 2016-04-04
Other Details LanguageAuthor name: Václav Papež
Organisation: University of West Bohemia
Email: vpapez@kiv.zcu.cz
Date originally authored: 2016-04-04
OtherDetails Language Independent{licence=This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/., custodian_organisation=openEHR Foundation, references=Based on odML terminology http://portal.g-node.org/odml/terminologies/v1.0/experiment/electrophysiology.xml, v.1.0, d. 2012-01-02 , original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=344CA243823B82B7345A26459A05FF9C, build_uid=438b6157-c12e-49ee-bd25-085917a41cad, revision=0.0.1-alpha}
Keywordsexperiment, electrophysiology
Lifecyclein_development
UID31fc8d28-8943-48c1-abc1-17a2e725990c
Language usedcs
Citeable Identifier1013.1.2592
Revision Number0.0.1-alpha
AllArchetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Properties for describing an electrophysiological experiment., archetypeConceptComment=null, otherContributors=, originalLanguage=cs, translators=, subjectOfData=unconstrained, archetypeTranslationTree=null, topLevelToAshis={source=[], identities=[], contacts=[], ism_transition=[], provider=[], protocol=[], description=[], events=[], details=[], context=[], target=[], capabilities=[], items=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=ELEMENT, level=1, text=Type, description=Intracellular recording of single cell responses with sharp microelectrodes., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=[ODMLID::ODMLID012002], values=
  • intracellular recording [*]
  • extracellular recording [*]
  • patch clamp [*]
  • whole cell patch [*]
  • loose patch [*]
  • ERG [*]
  • EEG [*]
  • EKG [*]
  • EMG [*]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0011], code=at0011, itemType=ELEMENT, level=1, text=Subtype, description=Subtype of this electrophysiological experiment., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=[ODMLID::ODMLID012003], values=
  • single electrode recording [*]
  • dual electrode recording [*]
  • multi electrode recording [*]
, extendedValues=null]], other_participations=[], content=[], state=[], activities=[], data=[], relationships=[], credentials=[]}, topLevelItems={items=ResourceSimplifiedHierarchyItem [path=ROOT_/, code=at0000, itemType=CLUSTER, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=items, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=ELEMENT, level=1, text=Type, description=Intracellular recording of single cell responses with sharp microelectrodes., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=[ODMLID::ODMLID012002], values=
  • intracellular recording [*]
  • extracellular recording [*]
  • patch clamp [*]
  • whole cell patch [*]
  • loose patch [*]
  • ERG [*]
  • EEG [*]
  • EKG [*]
  • EMG [*]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0011], code=at0011, itemType=ELEMENT, level=1, text=Subtype, description=Subtype of this electrophysiological experiment., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=[ODMLID::ODMLID012003], values=
  • single electrode recording [*]
  • dual electrode recording [*]
  • multi electrode recording [*]
, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null]