ARCHETYPE Eye fundus image acquisition and validation (openEHR-EHR-SECTION.eye_fundus_acquisition.v0)

ARCHETYPE IDopenEHR-EHR-SECTION.eye_fundus_acquisition.v0
ConceptEye fundus image acquisition and validation
DescriptionDefines the process of acquiring and validating eye fundus image studies.
UseUse to group acquisition and validation details during clinical studies including eye fundus imaging.
PurposeManage the process of acquiring eye fundus images, whilst every resulting image is validated for diagnostic purposes.
References
Copyright© openEHR Foundation
AuthorsAuthor name: Aitor Eguzkitza
Organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra
Email: aitor.eguzkiza@unavarra.es
Date originally authored: 2014-05-26
Other Details LanguageAuthor name: Aitor Eguzkitza
Organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra
Email: aitor.eguzkiza@unavarra.es
Date originally authored: 2014-05-26
OtherDetails Language Independent{licence=This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/., custodian_organisation=openEHR Foundation, original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=C3766D8562C65ADC424761BBD9F28FF6, build_uid=c3f83dcc-9720-45a8-aff3-a39f01d45f3a, revision=0.0.1-alpha}
Keywordsimaging
Lifecyclein_development
UIDb4b75321-1eae-4b8b-8975-40ecb70d5058
Language useden
Citeable Identifier1013.1.2121
Revision Number0.0.1-alpha
AllArchetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Defines the process of acquiring and validating eye fundus image studies., archetypeConceptComment=null, otherContributors=, originalLanguage=en, translators=
  • Spanish (Spain): ?

  • , subjectOfData=unconstrained, archetypeTranslationTree=null, topLevelToAshis={items=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=SLOT, level=1, text=Imaging acquisition, description=Clinical activity that takes place when conducting eye fundus image studies., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=Include:
    openEHR-EHR-ACTION.imaging_exam.v([0-9]+) and specialisations
    Exclude:
    All not explicitly included archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0003], code=at0003, itemType=SLOT, level=1, text=Image validation, description=Review of the eye fundus images acquired to validate their use for diagnostic purposes., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=OBSERVATION, bindings=null, values=Include:
    openEHR-EHR-OBSERVATION.fundoscopic_examination.v([0-9]+) and specialisations, extendedValues=null]], description=[], context=[], activities=[], identities=[], capabilities=[], provider=[], protocol=[], content=[], source=[], credentials=[], events=[], data=[], contacts=[], ism_transition=[], details=[], relationships=[], state=[], target=[], other_participations=[]}, topLevelItems={items=ResourceSimplifiedHierarchyItem [path=ROOT_/items[at0001], code=at0001, itemType=ACTION, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=items, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=SLOT, level=1, text=Imaging acquisition, description=Clinical activity that takes place when conducting eye fundus image studies., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=Include:
    openEHR-EHR-ACTION.imaging_exam.v([0-9]+) and specialisations
    Exclude:
    All not explicitly included archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0003], code=at0003, itemType=SLOT, level=1, text=Image validation, description=Review of the eye fundus images acquired to validate their use for diagnostic purposes., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=OBSERVATION, bindings=null, values=Include:
    openEHR-EHR-OBSERVATION.fundoscopic_examination.v([0-9]+) and specialisations, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null]