ARCHETYPE ID | openEHR-EHR-CLUSTER.corneal_thickness_details.v0 |
Concept | Central corneal thickness details |
Description | Measurement details about of the central corneal thickness. |
Use | As support test for fine-tune other measurements. For example to correct the intraocular pressure measurement. |
Purpose | To report measurements for the central corneal thickness. |
References | |
Copyright | © openEHR Foundation |
Authors | Author name: Aitor Eguzkitza Organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra Email: aitor.eguzkiza@unavarra.es Date originally authored: 2015-06-06 |
Other Details Language | Author name: Aitor Eguzkitza Organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra Email: aitor.eguzkiza@unavarra.es Date originally authored: 2015-06-06 |
OtherDetails Language Independent | {licence=This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/., custodian_organisation=openEHR Foundation, original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=3DE54ACFAC25ADA0DE7178C9BA0C74B6, build_uid=5d30e267-cf4f-48de-9686-40e69d91ad36, revision=0.0.1-alpha} |
Keywords | |
Lifecycle | in_development |
UID | 98142d61-b266-4228-b88f-b8ff11a2e948 |
Language used | en |
Citeable Identifier | 1013.1.2015 |
Revision Number | 0.0.1-alpha |
All | Archetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Measurement details about of the central corneal thickness., archetypeConceptComment=null, otherContributors=, originalLanguage=en, translators=, subjectOfData=unconstrained, archetypeTranslationTree=null, topLevelToAshis={protocol=[], credentials=[], description=[], ism_transition=[], provider=[], content=[], activities=[], relationships=[], contacts=[], details=[], capabilities=[], context=[], other_participations=[], state=[], events=[], source=[], items=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=ELEMENT, level=1, text=Central Corneal Thickness (CCT), description=Value measured of the central corneal thickness., comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=[SNOMED-CT: Units: 400.0..700.0 μm Limit decimal places: 2, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0002], code=at0002, itemType=ELEMENT, level=1, text=Measurement Method, description=Method used to measure the corneal thickness parameter., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=Constraint: Corneal thickness measurement devices [List of medical devices that include the functionality of corneal pachymetry.] , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0003], code=at0003, itemType=ELEMENT, level=1, text=Correction parameter, description=Parameter obtained from tables provided by manufacturers, to correct the intraocular pressure value according to the central corneal thickness obtained., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Pressure Units: -7.0..7.0 mmHg Limit decimal places: 1 Assumed value: 0.0mmHg Limit decimal places: 1, extendedValues=null]], identities=[], target=[], data=[]}, topLevelItems={items=ResourceSimplifiedHierarchyItem [path=ROOT_/, code=at0000, itemType=CLUSTER, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=1..*, cardinalityText= , subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=items, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=ELEMENT, level=1, text=Central Corneal Thickness (CCT), description=Value measured of the central corneal thickness., comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=[SNOMED-CT: Units: 400.0..700.0 μm Limit decimal places: 2, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0002], code=at0002, itemType=ELEMENT, level=1, text=Measurement Method, description=Method used to measure the corneal thickness parameter., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=Constraint: Corneal thickness measurement devices [List of medical devices that include the functionality of corneal pachymetry.] , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0003], code=at0003, itemType=ELEMENT, level=1, text=Correction parameter, description=Parameter obtained from tables provided by manufacturers, to correct the intraocular pressure value according to the central corneal thickness obtained., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Pressure Units: -7.0..7.0 mmHg Limit decimal places: 1 Assumed value: 0.0mmHg Limit decimal places: 1, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null] |