ARCHETYPE ID | openEHR-EHR-SECTION.intraocular_pressure_study.v0 |
Concept | Intraocular pressure study |
Description | Defines the process which involves the intraocular pressure acquisition and its study. |
Use | Any healthcare study that requires the measurement of intraocular pressure. |
Purpose | Manage the process of carrying out and then reviewing the test of intraocular pressure measurement. |
References | |
Copyright | © openEHR Foundation |
Authors | Author name: Aitor Eguzkitza Organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra Email: aitor.eguzkiza@unavarra.es Date originally authored: 2015-06-27 |
Other Details Language | Author name: Aitor Eguzkitza Organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra Email: aitor.eguzkiza@unavarra.es Date originally authored: 2015-06-27 |
OtherDetails Language Independent | {licence=This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/., custodian_organisation=openEHR Foundation, original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=B632D4D0515FC332223E0614809263D0, build_uid=d6a52f30-1d5b-4a27-aec0-2be6ba743540, revision=0.0.1-alpha} |
Keywords | IOP, intraocular pressure |
Lifecycle | in_development |
UID | b3af1944-4deb-46e4-a356-c6dfc45c293e |
Language used | en |
Citeable Identifier | 1013.1.1704 |
Revision Number | 0.0.1-alpha |
All | Archetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Defines the process which involves the intraocular pressure acquisition and its study., archetypeConceptComment=null, otherContributors=José Andonegui, Hospital de Navarra, jose.andonegui.navarro@cfnavarra.es Luis Serrano, Universidad Pública de Navarra (UPNA), lserrano@unavarra.es Jesús D. Trigo, Universidad Pública de Navarra (UPNA), jesusdaniel.trigo@unavarra.es, originalLanguage=en, translators= , subjectOfData=unconstrained, archetypeTranslationTree=null, topLevelToAshis={items=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=SLOT, level=1, text=Procedure undertaken, description=Describes the procedure/s carried out to obtain the intraocular pressure from the patient., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=Include: openEHR-EHR-ACTION.procedure.v([0-9]+) and specialisations Exclude: All not explicitly included archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0002], code=at0002, itemType=SLOT, level=1, text=IOP measurement, description=Examination of results for the intraocular pressure measurement of a single eye, normally using a tonometry device., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=OBSERVATION, bindings=null, values=Include: openEHR-EHR-OBSERVATION.intraocular_ Exclude: All not explicitly included archetypes, extendedValues=null]], description=[], context=[], activities=[], identities=[], capabilities=[], provider=[], protocol=[], content=[], source=[], credentials=[], events=[], data=[], contacts=[], ism_transition=[], details=[], relationships=[], state=[], target=[], other_participations=[]}, topLevelItems={items=ResourceSimplifiedHierarchyItem [path=ROOT_/items[at0001], code=at0001, itemType=ACTION, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=1..*, cardinalityText= , subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=items, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=SLOT, level=1, text=Procedure undertaken, description=Describes the procedure/s carried out to obtain the intraocular pressure from the patient., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=Include: openEHR-EHR-ACTION.procedure.v([0-9]+) and specialisations Exclude: All not explicitly included archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0002], code=at0002, itemType=SLOT, level=1, text=IOP measurement, description=Examination of results for the intraocular pressure measurement of a single eye, normally using a tonometry device., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=OBSERVATION, bindings=null, values=Include: openEHR-EHR-OBSERVATION.intraocular_ Exclude: All not explicitly included archetypes, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null] |