ARCHETYPE Intraocular pressure study (openEHR-EHR-SECTION.intraocular_pressure_study.v0)

ARCHETYPE IDopenEHR-EHR-SECTION.intraocular_pressure_study.v0
ConceptIntraocular pressure study
DescriptionDefines the process which involves the intraocular pressure acquisition and its study.
UseAny healthcare study that requires the measurement of intraocular pressure.
PurposeManage the process of carrying out and then reviewing the test of intraocular pressure measurement.
References
Copyright© openEHR Foundation
AuthorsAuthor name: Aitor Eguzkitza
Organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra
Email: aitor.eguzkiza@unavarra.es
Date originally authored: 2015-06-27
Other Details LanguageAuthor name: Aitor Eguzkitza
Organisation: Universidad Pública de Navarra - Complejo Hospitalario de Navarra
Email: aitor.eguzkiza@unavarra.es
Date originally authored: 2015-06-27
OtherDetails Language Independent{licence=This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/., custodian_organisation=openEHR Foundation, original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=B632D4D0515FC332223E0614809263D0, build_uid=d6a52f30-1d5b-4a27-aec0-2be6ba743540, revision=0.0.1-alpha}
KeywordsIOP, intraocular pressure
Lifecyclein_development
UIDb3af1944-4deb-46e4-a356-c6dfc45c293e
Language useden
Citeable Identifier1013.1.1704
Revision Number0.0.1-alpha
AllArchetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Defines the process which involves the intraocular pressure acquisition and its study., archetypeConceptComment=null, otherContributors=José Andonegui, Hospital de Navarra, jose.andonegui.navarro@cfnavarra.es
Luis Serrano, Universidad Pública de Navarra (UPNA), lserrano@unavarra.es
Jesús D. Trigo, Universidad Pública de Navarra (UPNA), jesusdaniel.trigo@unavarra.es, originalLanguage=en, translators=
  • Spanish (Spain): ?

  • , subjectOfData=unconstrained, archetypeTranslationTree=null, topLevelToAshis={items=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=SLOT, level=1, text=Procedure undertaken, description=Describes the procedure/s carried out to obtain the intraocular pressure from the patient., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=Include:
    openEHR-EHR-ACTION.procedure.v([0-9]+) and specialisations
    Exclude:
    All not explicitly included archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0002], code=at0002, itemType=SLOT, level=1, text=IOP measurement, description=Examination of results for the intraocular pressure measurement of a single eye, normally using a tonometry device., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=OBSERVATION, bindings=null, values=Include:
    openEHR-EHR-OBSERVATION.intraocular_pressure.v([0-9]+) and specialisations
    Exclude:
    All not explicitly included archetypes, extendedValues=null]], description=[], context=[], activities=[], identities=[], capabilities=[], provider=[], protocol=[], content=[], source=[], credentials=[], events=[], data=[], contacts=[], ism_transition=[], details=[], relationships=[], state=[], target=[], other_participations=[]}, topLevelItems={items=ResourceSimplifiedHierarchyItem [path=ROOT_/items[at0001], code=at0001, itemType=ACTION, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=items, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=SLOT, level=1, text=Procedure undertaken, description=Describes the procedure/s carried out to obtain the intraocular pressure from the patient., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=ACTION, bindings=null, values=Include:
    openEHR-EHR-ACTION.procedure.v([0-9]+) and specialisations
    Exclude:
    All not explicitly included archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0002], code=at0002, itemType=SLOT, level=1, text=IOP measurement, description=Examination of results for the intraocular pressure measurement of a single eye, normally using a tonometry device., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=OBSERVATION, bindings=null, values=Include:
    openEHR-EHR-OBSERVATION.intraocular_pressure.v([0-9]+) and specialisations
    Exclude:
    All not explicitly included archetypes, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null]