ARCHETYPE Myringotomy (openEHR-EHR-CLUSTER.myringotomy.v0)

ARCHETYPE IDopenEHR-EHR-CLUSTER.myringotomy.v0
ConceptMyringotomy
DescriptionSurgical procedure in which an incision is made in the tympanic membrane to relieve pressure and/or drain fluid. This is often accompanied by insertion of a ventilation tube to keep the middle ear aerated and prevent reaccumulation of fluid.
UseUse to record details about the myringotomy performed.
PurposeTo record details about the myringotomy performed.
ReferencesDerived from: Myringotomy, Draft Archetype [Internet]. Digital Health Agency, Australian Digital Health Agency Clinical Knowledge Manager. No longer available.
Copyright© openEHR Foundation
AuthorsAuthor name: Heather Leslie
Organisation: Ocean Informatics
Email: heather.leslie@oceaninformatics.com
Date originally authored: 2013-03-21
Other Details LanguageAuthor name: Heather Leslie
Organisation: Ocean Informatics
Email: heather.leslie@oceaninformatics.com
Date originally authored: 2013-03-21
OtherDetails Language Independent{custodian_organisation=openEHR Foundation, references=Derived from: Myringotomy, Draft Archetype [Internet]. Digital Health Agency, Australian Digital Health Agency Clinical Knowledge Manager. No longer available., current_contact=Heather Leslie, Ocean Informatics, heather.leslie@oceaninformatics.com, original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=BD0DBAE50DAF9188CA97E7FF6C92CDDF, build_uid=dc8518c3-48fc-4f94-99ec-baf33b426fcd, revision=0.0.1-alpha}
Keywordsoperation, myringotomy
Lifecyclein_development
UID743a77f3-2e26-4f2d-8aa4-8a959d73f88a
Language useden
Citeable Identifier1013.1.1674
Revision Number0.0.1-alpha
AllArchetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Surgical procedure in which an incision is made in the tympanic membrane to relieve pressure and/or drain fluid. This is often accompanied by insertion of a ventilation tube to keep the middle ear aerated and prevent reaccumulation of fluid., archetypeConceptComment=null, otherContributors=, originalLanguage=en, translators=, subjectOfData=unconstrained, archetypeTranslationTree=null, topLevelToAshis={source=[], identities=[], contacts=[], ism_transition=[], provider=[], protocol=[], description=[], events=[], details=[], context=[], target=[], capabilities=[], items=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=ELEMENT, level=1, text=Fluid, description=Description of the fluid observed in the middle ear., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • None [No fluid was present.]
  • Serous [Serous fluid was present.]
  • Mucoid [Pus was present.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0005], code=at0005, itemType=ELEMENT, level=1, text=Ventilation Tube Inserted, description=Was a ventilation tube inserted?, comment=Record as True if a Ventilation Tube was inserted., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=Allowed values: {true}, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0006], code=at0006, itemType=SLOT, level=1, text=Ventilation Tube, description=Details of the ventilation tubes inserted., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
openEHR-EHR-CLUSTER.device.v1 and specialisations, extendedValues=null]], other_participations=[], content=[], state=[], activities=[], data=[], relationships=[], credentials=[]}, topLevelItems={items=ResourceSimplifiedHierarchyItem [path=ROOT_/, code=at0000, itemType=CLUSTER, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=items, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=ELEMENT, level=1, text=Fluid, description=Description of the fluid observed in the middle ear., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • None [No fluid was present.]
  • Serous [Serous fluid was present.]
  • Mucoid [Pus was present.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0005], code=at0005, itemType=ELEMENT, level=1, text=Ventilation Tube Inserted, description=Was a ventilation tube inserted?, comment=Record as True if a Ventilation Tube was inserted., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=Allowed values: {true}, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0006], code=at0006, itemType=SLOT, level=1, text=Ventilation Tube, description=Details of the ventilation tubes inserted., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
openEHR-EHR-CLUSTER.device.v1 and specialisations, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null]