ARCHETYPE Refraction assessment (openEHR-EHR-OBSERVATION.refraction.v0)

ARCHETYPE IDopenEHR-EHR-OBSERVATION.refraction.v0
ConceptRefraction assessment
DescriptionAssessment of the refraction required to achieve optimal visual acuity.
UseUse to record the results of measurement of refraction. The 'Description' data element can be used to record simple narrative summary or as a means to integrate legacy data.
PurposeFor recording the results of a refraction assessment, either performed on the patient's usual correction or by refraction of the patient.
ReferencesVisual Acuity [Internet]. Wikipedia. Available from: http://en.wikipedia.org/wiki/Visual_acuity

Aylward W [Internet].Coding Visual Acuity, openEyes Project;2012.Available from http://www.openeyes.org.uk/documents/OpenEyes%20Coding%20Visual%20Acuity.pdf

IHE Eye Care Domain. General Eye Evaluation (GEE) [Internet]. IHE; 2012. Available from: http://www.ihe.net/Technical_Framework/upload/IHE_EyeCare_Supp_GEE_Rev1-1_TI_2012-06-29.pdf

Royal College of Opthalmologists. Cataract National Dataset for Adults [Internet]. 2011. Available from: http://www.rcophth.ac.uk/page.asp?section=583&sectionTitle=Cataract+National+Data+Set+for+Adults

CfH, UK. Do Once & Share - Glaucoma [Internet]. [cited 2012 Sep 26]. Available from: http://www.doasglaucoma.org/

DICOM Supplement 30 [Internet]. [cited 2012 Sep 26]. Available from: http://medical.nema.org/

Practical Ophthalmology: A Manual for Beginning Residents, 6th Edition [Paperback]
American Academy Of Ophthalmology (Author), Fred M. Wilson II (Editor), MD (Editor)
Copyright© openEHR Foundation
AuthorsAuthor name: Ian McNicoll
Organisation: Ocean Informatics, UK
Email: ian.mcnicoll@oceaninformatics.com
Date originally authored: 2012-07-18
Other Details LanguageAuthor name: Ian McNicoll
Organisation: Ocean Informatics, UK
Email: ian.mcnicoll@oceaninformatics.com
Date originally authored: 2012-07-18
OtherDetails Language Independent{licence=This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/., custodian_organisation=openEHR Foundation, references=Visual Acuity [Internet]. Wikipedia. Available from: http://en.wikipedia.org/wiki/Visual_acuity Aylward W [Internet].Coding Visual Acuity, openEyes Project;2012.Available from http://www.openeyes.org.uk/documents/OpenEyes%20Coding%20Visual%20Acuity.pdf IHE Eye Care Domain. General Eye Evaluation (GEE) [Internet]. IHE; 2012. Available from: http://www.ihe.net/Technical_Framework/upload/IHE_EyeCare_Supp_GEE_Rev1-1_TI_2012-06-29.pdf Royal College of Opthalmologists. Cataract National Dataset for Adults [Internet]. 2011. Available from: http://www.rcophth.ac.uk/page.asp?section=583§ionTitle=Cataract+National+Data+Set+for+Adults CfH, UK. Do Once & Share - Glaucoma [Internet]. [cited 2012 Sep 26]. Available from: http://www.doasglaucoma.org/ DICOM Supplement 30 [Internet]. [cited 2012 Sep 26]. Available from: http://medical.nema.org/ Practical Ophthalmology: A Manual for Beginning Residents, 6th Edition [Paperback] American Academy Of Ophthalmology (Author), Fred M. Wilson II (Editor), MD (Editor), current_contact=Ian McNicoll, Ocean Informatics, UK, ian.mcnicoll@oceaninformatics.com, original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=6BD8C77305478477140978EB190D5AE0, build_uid=5eccc82d-3264-4cef-a11a-16418c247f2d, ip_acknowledgements=This artefact includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyrighted material of the International Health Terminology Standards Development Organisation (IHTSDO). Where an implementation of this artefact makes use of SNOMED CT content, the implementer must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomedct or info@snomed.org., revision=0.0.1-alpha}
Keywordseye, sight, vision, ophthalmic, visual, refraction, refraction, correction
Lifecyclein_development
UID098f8a46-e359-4a1d-9fec-5a5afce6dd81
Language useden
Citeable Identifier1013.1.1399
Revision Number0.0.1-alpha
AllArchetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=[SNOMED-CT::252886007 | Refraction assessment], archetypeConceptDescription=Assessment of the refraction required to achieve optimal visual acuity., archetypeConceptComment=null, otherContributors=Gustavo M Bacelar-Silva, Brazil, originalLanguage=en, translators=
  • Norwegian Bokmål: Thomas Baerland, Oslo Universitetssykehus / DIPS ASA, tba@dips.no, ?

  • , subjectOfData=unconstrained, archetypeTranslationTree=null, topLevelToAshis={state=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/state[at0041]/items[at0112], code=at0112, itemType=ELEMENT, level=4, text=Confounding Factors, description=Patient circumstances which affect interpretation of the result. Often termed 'reliability' in opthalmological documentation., comment=Examples: 'Patient was confused', 'Low light conditions'., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/state[at0041]/items[at0042], code=at0042, itemType=ELEMENT, level=4, text=Refractive Correction, description=The specific type(s) of refractive correction applied., comment=Examples: 'No correction : unaided', 'Pinhole'., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=, extendedValues=null]], contacts=[], details=[], description=[], content=[], provider=[], data=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0039], code=at0039, itemType=ELEMENT, level=4, text=Description, description=An overall narrative description of the visual acuity test result., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=[SNOMED-CT::117364006 | Narrative value], values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053], code=at0053, itemType=CLUSTER, level=4, text=Result details, description=Details of the refraction result for each eye., comment=null, uncommonOntologyItems=null, occurencesFormal=0..2, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0144], code=at0144, itemType=ELEMENT, level=5, text=Test eye, description=Identification of the eye which is being tested., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
    • Right eye [Assessment of the right eye was performed.]
    • Left eye [Assessment of the left eye was performed.]
    , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0139], code=at0139, itemType=SLOT, level=5, text=Refraction details, description=Details of refraction for a single eye., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
    openEHR-EHR-CLUSTER.refraction_details.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0055], code=at0055, itemType=ELEMENT, level=5, text=No test result, description=No refraction test result is available for the test eye., comment=Record as True if the clinician was unable to record a result for the test eye., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=Allowed values: {true}, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0147], code=at0147, itemType=ELEMENT, level=5, text=Reason for no test result, description=Reason why no refraction result is available for the test eye., comment=For example, patient was not cooperative; patient was not capable; ran out of time., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0066], code=at0066, itemType=ELEMENT, level=5, text=Interpretation, description=The test result expressed as a qualitative term, normally coded., comment=Example: "Visual Acuity 20/20" or "Jaeger 'J2' score"., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=[SNOMED-CT::366060000 | Refraction measurement - finding], values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0054], code=at0054, itemType=ELEMENT, level=4, text=Overall interpretation, description=A term, commonly coded, expressing an overall interpretation of the visual acuity test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=[SNOMED-CT::366060000 | Refraction measurement - finding], values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0040], code=at0040, itemType=ELEMENT, level=4, text=Comment, description=Any additional narrative comment about the visual acuity test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=[SNOMED-CT::117364006 | Narrative value], values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0140], code=at0140, itemType=SLOT, level=4, text=Examination not done, description=Details to explicitly record that this test was not performed., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
    openEHR-EHR-CLUSTER.exclusion_exam.v1 and specialisations, extendedValues=null]], identities=[], other_participations=[], activities=[], protocol=[ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0025], code=at0025, itemType=SLOT, level=2, text=Device Details, description=Details of the device used to measure refraction., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
    openEHR-EHR-CLUSTER.device.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0141], code=at0141, itemType=SLOT, level=2, text=Extension, description=Additional information required to capture local content or to align with other reference models/formalisms., comment=For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
    All not explicitly excluded archetypes, extendedValues=null]], credentials=[], events=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134], code=at0134, itemType=EVENT, level=2, text=Any event, description=Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=EVENT, bindings=null, values=null, extendedValues=null]], context=[], relationships=[], target=[], capabilities=[], items=[], source=[], ism_transition=[]}, topLevelItems={state=ResourceSimplifiedHierarchyItem [path=ROOT_/data[at0001]/events[at0134]/state[at0041], code=at0041, itemType=ITEM_TREE, level=2, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=0..1, cardinalityText=optional, subCardinalityFormal=0..*, subCardinalityText=Minimum of 0 items, dataType=ITEM_TREE, bindings=null, values=null, extendedValues=null], data=ResourceSimplifiedHierarchyItem [path=ROOT_/data[at0001]/events[at0134]/data[at0003], code=at0003, itemType=ITEM_TREE, level=2, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=0..1, cardinalityText=optional, subCardinalityFormal=0..*, subCardinalityText=Minimum of 0 items, dataType=ITEM_TREE, bindings=null, values=null, extendedValues=null], protocol=ResourceSimplifiedHierarchyItem [path=ROOT_/protocol[at0020], code=at0020, itemType=ITEM_TREE, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=0..1, cardinalityText=optional, subCardinalityFormal=0..*, subCardinalityText=Minimum of 0 items, dataType=ITEM_TREE, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=protocol, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0025], code=at0025, itemType=SLOT, level=2, text=Device Details, description=Details of the device used to measure refraction., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
    openEHR-EHR-CLUSTER.device.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0141], code=at0141, itemType=SLOT, level=2, text=Extension, description=Additional information required to capture local content or to align with other reference models/formalisms., comment=For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
    All not explicitly excluded archetypes, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null]