ARCHETYPE ID | openEHR-EHR-OBSERVATION.visual_field_measurement.v0 |
Concept | Visual field measurement |
Description | Results of visual field testing / perimetry. |
Use | Use to record the results of visual field testing or perimetry. Use to incorporate the narrative descriptions of clinical findings within existing or legacy clinical systems into an archetyped format, using the 'Clinical Description' data element. Detailed, structured visual acuity results are preferred and are generally recorded for each eye in turn. If the method of measurement or device is changed for the testing of the second eye, record the second eye's data in another instance of data which captures the new method or device. |
Purpose | To record the results of visual field testing or perimetry. |
References | IHE Eye Care Domain. General Eye Evaluation (GEE) [Internet]. IHE; 2012. Available from: http://www.ihe.net/Technical_Framework/upload/IHE_EyeCare_Supp_GEE_Rev1-1_TI_2012-06-29.pdf Royal College of Opthalmologists. Cataract National Dataset for Adults [Internet]. 2011. Available from: http://www.rcophth.ac.uk/page.asp?section=583§ionTitle=Cataract+National+Data+Set+for+Adults CfH, UK. Do Once & Share - Glaucoma [Internet]. [cited 2012 Sep 26]. Available from: http://www.doasglaucoma.org/ DICOM Supplement 142 [Internet]: Ophthalmic Visual Field (OPV) Static Perimetry Measurements Storage SOP Class. [cited 2013 May 28]. Available from: http://medical.nema.org/ http://www.slideshare.net/hmirzaeee/glaucoma-hemifield-test Standard Automated Perimetry, EyeWiki, http://eyewiki.aao.org/Standard_Automated_Perimetry Test strategies: Bengtsson B, Olsson J, Heijl A, Rootzen H. A new generation of algorithms for computerized threshold perimetry, SITA. Acta Ophthalmologica Scandinavica, 1997, 75: 368-375. Bengtsson B, Hejl A. SITA Fast, a new rapid perimetric threshold test. Description of methods and evaluation in patients with manifest and suspect glaucoma. Acta Ophthalmologica Scandinavica, 1998, 76: 431-437. Flanagan JG, Wild JM, Trope GE. Evaluation of FASTPAC, a new strategy for threshold estimation with the Humphrey Field Analyzer, in a glaucomatous population. Ophthalmology, 1993, 100: 949-954. Morales J, Weitzman ML, Gonzalez de la Rosa M. Comparison between Tendency-Oriented Perimetry (TOP) and octopus threshold perimetry. Ophthalmology, 2000, 107: 134-142. Chiefer U, Pascual JP, Edmunds B, Feudner E, Hoffmann EM, Johnson CA, Lagreze WA, Pfeiffer N, Sample PA, Staubach F, Weleber RG, Vonthein R, Krapp E, Paetzold J. Comparison of the new perimetric GATE strategy with conventional full-threshold and SITA standard strategies. Investigative Ophthalmology and Visual Science, 2009, 51: 488-494. |
Copyright | © openEHR Foundation |
Authors | Author name: Ian McNicoll Organisation: Ocean Informatics UK Email: ian.mcnicoll@oceaninformatics.com Date originally authored: 2012-09-19 |
Other Details Language | Author name: Ian McNicoll Organisation: Ocean Informatics UK Email: ian.mcnicoll@oceaninformatics.com Date originally authored: 2012-09-19 |
OtherDetails Language Independent | {licence=This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/., custodian_organisation=openEHR Foundation, references=IHE Eye Care Domain. General Eye Evaluation (GEE) [Internet]. IHE; 2012. Available from: http://www.ihe.net/Technical_Framework/upload/IHE_EyeCare_Supp_GEE_Rev1-1_TI_2012-06-29.pdf Royal College of Opthalmologists. Cataract National Dataset for Adults [Internet]. 2011. Available from: http://www.rcophth.ac.uk/page.asp?section=583§ionTitle=Cataract+National+Data+Set+for+Adults CfH, UK. Do Once & Share - Glaucoma [Internet]. [cited 2012 Sep 26]. Available from: http://www.doasglaucoma.org/ DICOM Supplement 142 [Internet]: Ophthalmic Visual Field (OPV) Static Perimetry Measurements Storage SOP Class. [cited 2013 May 28]. Available from: http://medical.nema.org/ http://www.slideshare.net/hmirzaeee/glaucoma-hemifield-test Standard Automated Perimetry, EyeWiki, http://eyewiki.aao.org/Standard_Automated_Perimetry Test strategies: Bengtsson B, Olsson J, Heijl A, Rootzen H. A new generation of algorithms for computerized threshold perimetry, SITA. Acta Ophthalmologica Scandinavica, 1997, 75: 368-375. Bengtsson B, Hejl A. SITA Fast, a new rapid perimetric threshold test. Description of methods and evaluation in patients with manifest and suspect glaucoma. Acta Ophthalmologica Scandinavica, 1998, 76: 431-437. Flanagan JG, Wild JM, Trope GE. Evaluation of FASTPAC, a new strategy for threshold estimation with the Humphrey Field Analyzer, in a glaucomatous population. Ophthalmology, 1993, 100: 949-954. Morales J, Weitzman ML, Gonzalez de la Rosa M. Comparison between Tendency-Oriented Perimetry (TOP) and octopus threshold perimetry. Ophthalmology, 2000, 107: 134-142. Chiefer U, Pascual JP, Edmunds B, Feudner E, Hoffmann EM, Johnson CA, Lagreze WA, Pfeiffer N, Sample PA, Staubach F, Weleber RG, Vonthein R, Krapp E, Paetzold J. Comparison of the new perimetric GATE strategy with conventional full-threshold and SITA standard strategies. Investigative Ophthalmology and Visual Science, 2009, 51: 488-494., current_contact=Ian McNicoll, Ocean Informatics, UK, ian.mcnicoll@oceaninformatics.com, original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=4F42F4B685A2B9CD1C4A3FC05D64BB63, build_uid=60dc0470-6574-47bd-836f-963776e4dcd6, ip_acknowledgements=This artefact includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyrighted material of the International Health Terminology Standards Development Organisation (IHTSDO). Where an implementation of this artefact makes use of SNOMED CT content, the implementer must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomedct or info@snomed.org., revision=0.0.1-alpha} |
Keywords | perimetry, ophthalmic, optometry, eye, vision, visual |
Lifecycle | in_development |
UID | af0c9a40-9ee3-4068-a492-00e994d1812f |
Language used | en |
Citeable Identifier | 1013.1.1370 |
Revision Number | 0.0.1-alpha |
All | Archetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Results of visual field testing / perimetry., archetypeConceptComment=null, otherContributors=José Andonegui, Hospital de Navarra, jose.andonegui.navarro@cfnavarra.es Gustavo Bacelar-Silva, Healthcare Designs, Brazil (openEHR Editor) Aitor Eguzkitza, Universidad Pública de Navarra - Complejo Hospitalario de Navarra, aitor.eguzkiza@unavarra.es Ian McNicoll, freshEHR Clinical Informatics, United Kingdom (openEHR Editor) Luis Serrano, Universidad Pública de Navarra (UPNA), lserrano@unavarra.es John Tore Valand, Helse Bergen, Norway (openEHR Editor), originalLanguage=en, translators=, subjectOfData=unconstrained, archetypeTranslationTree=null, topLevelToAshis={events=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002], code=at0002, itemType=EVENT, level=2, text=Any event, description=Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=EVENT, bindings=null, values=null, extendedValues=null]], content=[], identities=[], description=[], relationships=[], target=[], ism_transition=[], data=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0052], code=at0052, itemType=ELEMENT, level=4, text=Test result name, description=Identification of the visual field test being performed, by name., comment=In DICOM this is defined as a visual field global index (0024,0325)). Values permitted are defined by DICOM standard (PS 3.16) inside the table with Context ID 4257., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
Assumed value: Glaucoma Hemifield Test Analysis (GHT), extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0005], code=at0005, itemType=ELEMENT, level=4, text=Clinical description, description=Narrative description of the overall findings observed during the test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007], code=at0007, itemType=CLUSTER, level=4, text=Test result, description=Details of the visual field test result for each eye., comment=null, uncommonOntologyItems=null, occurencesFormal=0..2, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText= , subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0008], code=at0008, itemType=ELEMENT, level=5, text=Eye examined, description=The eye which is being examined., comment=Matches to DICOM Laterality (0020,0060) attribute., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
Units: -100.0..100.0 dB Limit decimal places: 2, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0037], code=at0037, itemType=ELEMENT, level=5, text=Visual Field Index (VFI), description=Visual Field Index result., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_PROPORTION, bindings=[SNOMED-CT:
Assumed value: false , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0034], code=at0034, itemType=ELEMENT, level=5, text=Mean Deviation (MD), description=Weighted average deviation from the age corrected normal field, in dB., comment=Matches to DICOM (0024,0066) attribute., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=[SNOMED-CT: Units: -30.0..10.0 dB Limit decimal places: 2, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0038], code=at0038, itemType=ELEMENT, level=5, text=Mean Deviation P (MD), description=The P value of the Mean Deviation result., comment=Matches to DICOM (0024,0083) attribute., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_PROPORTION, bindings=null, values=
Assumed value: false , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0035], code=at0035, itemType=ELEMENT, level=5, text=Pattern Standard Deviation (PSD), description=Average of non-uniform visual field loss or weighted square root of loss variance, in dB., comment=Matches to DICOM (0024,0068) attribute., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=[SNOMED-CT: Units: 0.0..25.0 dB Limit decimal places: 2, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0039], code=at0039, itemType=ELEMENT, level=5, text=Pattern Standard Deviation P (PSD), description=The P value of the Pattern Standard deviation result., comment= Matches to DICOM (0024,0073) attribute., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_PROPORTION, bindings=null, values=
Assumed value: false , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0058], code=at0058, itemType=ELEMENT, level=5, text=Short-Term Fluctuation (SF), description=Average deviation of sensitivity for the repeated test locations, in dB. This is used to determine the consistency of the patient’s responses., comment=Matches to DICOM (0024,0075) attribute., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Loudness Units: dB, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0059], code=at0059, itemType=ELEMENT, level=5, text=Corrected Pattern Standard Deviation (CPSD), description=Weighted square root of loss variance corrected for short term fluctuation, in dB., comment=Matches to DICOM (0024,0079) attribute., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Loudness Units: dB Limit decimal places: 3, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0027], code=at0027, itemType=ELEMENT, level=5, text=Perimetry test interpretation, description=A coded intepretation of the Visual field test result., comment=Values permitted are defined by DICOM standard (PS 3.16) inside the table with Context ID 4254., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=[SNOMED-CT:
Assumed value: Within normal limits, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0174], code=at0174, itemType=ELEMENT, level=5, text=No test result, description=No visual field test result is available for the eye examined., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0175], code=at0175, itemType=ELEMENT, level=5, text=Reason for no test result, description=Reason why no visual field test result is available for the eye examined., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0171], code=at0171, itemType=SLOT, level=5, text=Multimedia, description=Digital representation of the test results., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include: openEHR-EHR-CLUSTER.multimedia.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0009], code=at0009, itemType=ELEMENT, level=5, text=Clinical interpretation, description=Clinical interpretation of all measurements for the test eye., comment=Coding with a terminology is preferred, where possible., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0007]/items[at0173], code=at0173, itemType=ELEMENT, level=5, text=Comment, description=Additional narrative about the visual field testing for the eye examined, not captured in other fields., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0025], code=at0025, itemType=ELEMENT, level=4, text=Overall interpretation, description=Overall clinical interpretation of the measurements and related findings of visual field testing., comment=Coding with a terminology is preferred, where possible. This data element is effectively an opthalmological diagnosis., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0172], code=at0172, itemType=SLOT, level=4, text=Test not done, description=Details to explicitly record that this test was not performed., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include: openEHR-EHR-CLUSTER.exclusion_ openEHR-EHR-CLUSTER.device.v1 and specialisations Exclude: All not explicitly included archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0010]/items[at0170], code=at0170, itemType=SLOT, level=2, text=Acquisition details, description=Details about the strategy to conduct the visual field test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include: openEHR-EHR-CLUSTER.acquisition_ , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/state[at0022]/items[at0049], code=at0049, itemType=ELEMENT, level=4, text=Patient not properly fixated quantity, description=The number of times the patient’s gaze is not properly fixated., comment=Matches to DICOM (0024,0036) attribute., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_COUNT, bindings=null, values=min: >=0; max: <=100 , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/state[at0022]/items[at0056], code=at0056, itemType=ELEMENT, level=4, text=False positives estimate, description=Estimated percentage of all patient responses that occurred at a time when no visual stimulus was present (false positive responses), as percent., comment=Matches to DICOM (0024,0054) attribute., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_PROPORTION, bindings=null, values=
Assumed value: false , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/state[at0022]/items[at0057], code=at0057, itemType=ELEMENT, level=4, text=False negatives estimate, description=Estimated percentage of all stimuli that were not seen by the patient but were previously seen at a lower luminance earlier in the visual field test (false negative responses), as percent. Matches to DICOM (0024,0046) attribute., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_PROPORTION, bindings=null, values=
Assumed value: false , extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/state[at0022]/items[at0023], code=at0023, itemType=ELEMENT, level=4, text=Confounding factors, description=Patient circumstances which may affect interpretation of the result., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/state[at0022]/items[at0036], code=at0036, itemType=SLOT, level=4, text=Refractive correction, description=Details of refractive correction applied to each eye., comment=null, uncommonOntologyItems=null, occurencesFormal=0..2, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include: openEHR-EHR-CLUSTER.refraction_ openEHR-EHR-CLUSTER.exam_ openEHR-EHR-CLUSTER.device.v1 and specialisations Exclude: All not explicitly included archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0010]/items[at0170], code=at0170, itemType=SLOT, level=2, text=Acquisition details, description=Details about the strategy to conduct the visual field test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include: openEHR-EHR-CLUSTER.acquisition_ |